10. Modeling results E#

10.1. Tested values#

Identification

Reference

Type

Tolerance

Loading 1

Normal contact force

2.0784E+05N

ANALYTIQUE

RELATIF — 5.00%

Tangential contact force

-1.2000E+05 N

ANALYTIQUE

RELATIF — 5.00%

DX (point A)

1,000 mm

NON_REGRESSION

RELATIF — 1.00%

DY (point A)

—1,732 mm

NON_REGRESSION

RELATIF — 1.00%

DX (point B)

1,000 mm

NON_REGRESSION

RELATIF — 1.00%

DY (point B)

—1,732 mm

NON_REGRESSION

RELATIF — 1.00%

DX (point C)

1,000 mm

NON_REGRESSION

RELATIF — 1.00%

DY (point C)

—1,732 mm

NON_REGRESSION

RELATIF — 1.00%

DX (point D)

1,000 mm

NON_REGRESSION

RELATIF — 1.00%

DY (point D)

—1,732 mm

NON_REGRESSION

RELATIF — 1.00%

Loading 2

Normal contact force

1, 722E+05N

ANALYTIQUE

RELATIF — 5.00%

Tangential contact force

—1.8173E+05N

ANALYTIQUE

RELATIF — 5.00%

DX (dot A)

1,000 mm

NON_REGRESSION

RELATIF — 2, 30%

DY (point A)

—1,732 mm

NON_REGRESSION

RELATIF — 1.00%

DX (point B)

1,000 mm

NON_REGRESSION

RELATIF — 1.00%

DY (point B)

—1,732 mm

NON_REGRESSION

RELATIF — 1.00%

DX (point C)

1,000 mm

NON_REGRESSION

RELATIF — 1.00%

DY (point C)

—1,732 mm

NON_REGRESSION

RELATIF — 1.00%

DX (point D)

1,000 mm

NON_REGRESSION

RELATIF — 1.00%

DY (point D)

—1,732 mm

NON_REGRESSION

RELATIF — 1.00%

Loading 3

Normal contact force

1, 71486E+05N

ANALYTIQUE

RELATIF — 5.00%

Tangential contact force

—1, 82977E+05N

ANALYTIQUE

RELATIF — 5.00%

DX (point A)

8.794mm

NON_REGRESSION

RELATIF — 1.00%

DY (point A)

2.76mm

NON_REGRESSION

RELATIF — 1.00%

DX (point B)

8.794mm

NON_REGRESSION

RELATIF — 1.00%

DY (point B)

2.768mm

NON_REGRESSION

RELATIF — 1.00%

DX (point C)

8.794mm

NON_REGRESSION

RELATIF — 1.00%

DY (point C)

2.768 mm

NON_REGRESSION

RELATIF — 1.00%

DX (point D)

8.794mm

NON_REGRESSION

RELATIF — 1.00%

DY (point D)

2.768 mm

NON_REGRESSION

RELATIF — 1.00%

10.2. notes#

  • The game is defined in this case by a function, the results are identical to those found in modeling I.

  • The normal and tangential pressures in the contact zone are verified by testing the overall contact force in the normal and tangential directions:

_images/Object_11.svg _images/Object_12.svg

(Charging 2)

_images/Object_13.svg

(Loading 3)