10. Results of D, F models#
10.1. Tested values of D, F models#
The calculation is non-linear because of the shock and no analytical solution is available. Compared to modeling C, the values obtained are different because the time diagram introduces numerical dissipation. We test the calculation on non-regression values on the displacement along \(x\) of the node \(\mathit{NO}2\).
Time (s) |
Reference |
Tolerance |
0.1 |
—15,6911E-3 |
|
0.2 |
—49,4505E-3 |
|
0.3 |
30.2638E-3 |
|
0.4 |
—38,0509E-3 |
|
0.5 |
—39,2295E-3 |
|