8. Results of C, E models#
8.1. Tested values of C, E modeling#
The calculation is non-linear because of the shock and no analytical solution is available. We therefore test the calculation on non-regression values on the displacement along \(x\) of the node \(\mathrm{NO2}\).
Time (s) |
Reference |
0.1 |
—15.6520E-3 |
0.2 |
—51.4832E-3 |
0.3 |
28,1291E-3 |
0.4 |
—44,9343E-3 |
0.5 |
—37.7508E-3 |
We compare the absolute movements from DYNA_NON_LINE with keyword SCHEMA_TEMPS (FORMULATION =” ACCELERATION “) with those given by DYNA_NON_LINE with keyword SCHEMA_TEMPS (FORMULATION =” DEPLACEMENT”).
Figure 8.1-a :: ** Comparison of DYNA_TRAN_EXPLI and DYNA_NON_LINE.