v3.05.300 SSLX300 — Validation of the COMBINAISON_CHARGE macro-command for the combination of mechanical and thermal loads#

Summary:

The objective of this test is to validate order COMBINAISON_CHARGE in the case of a mixture of different models: 3D model, shell models (DKT, COQUE_3D) and beam model (elements POU_D_E), and a mixture of different types of mechanical and thermal loads.

Four models use the mesh of the sdnv112a test case to test different cases:

  • sslx300a: mix of models: DKT, POU_D_T, POU_D_E

  • sslx300b: mix of models: DKT, POU_D_EM, POU_D_TGM

  • sslx300c: mix of models: DKT, BARRE,, POU_D_T, DIS_T

  • sslx300d: mix of models: DKT, BARRE,, POU_D_T, DIS_TR

Five models use the sslx100c test case mesh to test different cases:

  • sslx300e: mix of models: 3D, COQUE_3D, POU_D_E, DIS_TR

  • sslx300f: mix of models: 3D, DKT,, MEMBRANE, CABLE, DIS_TR

  • sslx300g: mix of models: 3D, COQUE_3D,, POU_D_E, GRILLE_MEMBRANE, DIS_TR

  • sslx300h: mix of models: 3D, DKT,, POU_D_E, GRILLE_EXCENTRE, DIS_TR

  • sslx300i: mix of models: 3D, COQUE_3D, 2D_ BARRE, GRILLE_MEMBRANE, DIS_TR