8. F modeling#

8.1. Characteristics of the model#

We use the macro command COMBINAISON_CHARGE for a mixture of models: 3D, DKT, MEMBRANE, CABLE, DIS_TR.

8.2. Tested sizes and results#

We test the « COEF_COMB » combinations in the coefficient table:

INTITULE

Size

Reference

Tolerance (%)

COMB_12

n7_ MAX

1, 0

1E-4

COMB_12

n8_ MIN

1,0

1E-4

We test the « CALC_COMB » combinations in the results table:

INTITULE

CMP

EXTREMA

Reference

Tolerance (%)

COMB_13

N

MAXI_ABS

40956.368120

1E-4

COMB_18

N

MAX

61568.182426

1E-4

COMB_14

DX

MAX

22116953.60

1E-4

COMB_16

DX

MIN

-24000088.65427

1E-4

We test « EXTREMA » combinations in the envelope table:

CMP

EXTREMA

Reference

Tolerance (%)

N

MAX

COMB_15

N

MAXI_ABS

COMB_15

DY

MAXI_ABS

75000.0

1E-4

DY

MAXI_ABS

COMB_18

DY

MAXI_ABS

75000.0

1E-4