5. C modeling#

5.1. Characteristics of the model#

We use the macro command COMBINAISON_CHARGE for a mix of models: DKT, BARRE, POU_D_T, DIS_T.

We use a DKT model for the walls, floors and the base, a POU_D_T model for the beams, a BARRE model for the columns and a DIS_T model for the center of the floor.

5.2. Characteristics of the mesh#

The mesh consists of: 19 SEG2

793 QUAD4

5.3. Tested sizes and results#

We test the « COEF_COMB » combinations in the coefficient table:

INTITULE

Size

Reference

Tolerance (%)

COMB_18

n12_ MIN

1.5

1E-4

COMB_15

n13_ MAX

1,0

1E-4

We test the « CALC_COMB » combinations in the results table:

INTITULE

CMP

EXTREMA

Reference

Tolerance (%)

COMB_13

N

MAXI_ABS

10802,187851

1E-4

COMB_18

N

MIN

-13667,449687

1E-4

COMB_14

SIXX

MAX

44089229,48744

1E-4

COMB_16

SIXX

MIN

-32506840,28023

1E-4

We test « EXTREMA » combinations in the envelope table:

CMP

EXTREMA

Reference

Tolerance (%)

N

MAX

COMB_7

VY

MAX

COMB_17

VY

MAX

76713,146696

1E-4

SIYY

MAXI_ABS

COMB_17

SIYY

MAXI_ABS

201619296,9582

1E-4