7. Modeling E#

7.1. Characteristics of the model#

We use the macro command COMBINAISON_CHARGE for a mixture of models: 3D, COQUE_3D, POU_D_E, DIS_TR.

7.2. Tested sizes and results#

We test the « COEF_COMB » combinations in the coefficient table:

INTITULE

Size

Reference

Tolerance (%)

COMB_18

n7_ MIN

1, 2

1E-4

COMB_15

n8_ MAX

1, 5

1E-4

We test the « CALC_COMB » combinations in the results table:

INTITULE

CMP

EXTREMA

Reference

Tolerance (%)

COMB_15

VY

MIN

-1200,0

1E-4

COMB_21

VY

MAXI_ABS

11000,0

1E-4

COMB_14

SIXX

MAX

11885566,2010

1E-4

COMB_16

SIXX

MIN

-22057255,75835

1E-4

We test « EXTREMA » combinations in the envelope table:

CMP

EXTREMA

Reference

Tolerance (%)

VY

MAXI_ABS

COMB_19

VZ

MAXI_ABS

COMB_15

X

MAX

0.01842611

0.01842611

1E-4

SIYY

MAXI_ABS

COMB_15

SIYY

MAXI_ABS

508355,43093