10. H modeling#

10.1. Characteristics of the model#

We use the macro command COMBINAISON_CHARGE for a mixture of models: 3D, DKT,, POU_D_E, GRILLE_EXCENTRE, DIS_TR.

10.2. Tested sizes and results#

We test the « COEF_COMB » combinations in the coefficient table:

INTITULE

Size

Reference

Tolerance (%)

COMB_12

n8_ MIN

1, 0

1E-4

COMB_12

n7_ MAX

1,0

1E-4

We test the « CALC_COMB » combinations in the results table:

INTITULE

CMP

EXTREMA

Reference

Tolerance (%)

COMB_13

N

MAXI_ABS

3817749,70737

1E-4

COMB_18

N

MAX

5727824,56105

1E-4

COMB_14

SIXX

MAX

14132937,1036

1E-4

COMB_16

SIXX

MIN

-14009367,37807

1E-4

We test « EXTREMA » combinations in the envelope table:

CMP

EXTREMA

Reference

Tolerance (%)

N

MAX

COMB_15

N

MAX

COMB_15

SIXX

MAXI_ABS

20824397,75389

1E-4

SIYY

MAXI_ABS

COMB_5

SIYY

MAXI_ABS

153670,2751

1E-4