2. Benchmark solution#

2.1. Calculation method#

The calculation of the semi-analytical solution is detailed in [1] (§2.1).

2.2. Reference quantities and results#

The vertical displacement calculated at point O in the semi-analytical model is specified below:

Size

Identification

Reference Solution

Displacement

Point \(O\) - \(\mathit{DZ}\)

-6,352 \(m\)

2.3. Uncertainties about the solution#

Semi-analytical solution: the numerical resolution of the equation gives a value to within \({10}^{-3}\).

2.4. Bibliographical references#

  1. SSNL114 — Heavy cable with thermal expansion, Code_Aster validation documentation. [V6.02.114].