2. Benchmark solution#
2.1. Calculation method#
The calculation of the semi-analytical solution is detailed in [1] (§2.1).
2.2. Reference quantities and results#
The vertical displacement calculated at point O in the semi-analytical model is specified below:
Size |
Identification |
Reference Solution |
Displacement |
Point \(O\) - \(\mathit{DZ}\) |
-6,352 \(m\) |
2.3. Uncertainties about the solution#
Semi-analytical solution: the numerical resolution of the equation gives a value to within \({10}^{-3}\).
2.4. Bibliographical references#
SSNL114 — Heavy cable with thermal expansion, Code_Aster validation documentation. [V6.02.114].