Benchmark solution ===================== Calculation method ----------------- The calculation of the semi-analytical solution is detailed in :ref:`[1] ` (§2.1). Reference quantities and results ------------------------ The vertical displacement calculated at point O in the semi-analytical model is specified below: .. csv-table:: "**Size**", "**Identification**", "**Reference Solution**" "Displacement", "Point :math:`O` - :math:`\mathit{DZ}` ", "-6,352 :math:`m`" Uncertainties about the solution ---------------------------- Semi-analytical solution: the numerical resolution of the equation gives a value to within :math:`{10}^{-3}`. Bibliographical references --------------------------- .. _RefHeading__3429_477645202: 1. SSNL114 — Heavy cable with thermal expansion, *Code_Aster* validation documentation. [:ref:`V6.02.114 `].