4. B modeling#

4.1. Characteristics of modeling#

It is the same modeling as modeling A, but with plane constraints, C_ PLAN. The junctions are constructed in the same way.

4.2. Characteristics of the mesh#

The mesh, which comprises 176 cells of the TRIA3 type, is represented in FIG. 4.2-a.

_images/10000000000000F0000000D7584FF94BB392CC47.png

Figure 4.2-a: The modeling B mesh.

4.3. Tested sizes and results#

The quantities tested are identical to those used for modeling A.

Identification

Reference

% tolerance

1.00E-11

DEPZON_1

DX

MIN

-0.25

MAX

-0.25

1.00E-11

DY

MIN

0

1.00E-11

MAX

0

1.00E-11

DEPZON_2

DX

MIN

-0.5

1.00E-11

MAX

-0.5

1.00E-11

DY

MIN

0

1.00E-11

MAX

0

1.00E-11

DEPZON_3

DX

MIN

0.75

1.00E-11

MAX

0.75

1.00E-11

DY

MIN

0

1.00E-11

MAX

0

1.00E-11

DEPZON_4

DX

MIN

0.75

1.00E-11

MAX

0.75

1.00E-11

DY

MIN

0

1.00E-11

MAX

0

1.00E-11

Table 4.3-1

The deformation is represented in FIG. 4.4-a.

_images/10000000000001BA0000014F05A95DEDA92821EE.jpg

Figure 4.4-a: Deformed structure.

We test the value of \({E}^{e}\) produced by the POST_ERREUR operator.

Identification

Reference type

Reference value

Ee

“ANALYTIQUE”

0

We test the value of \({\parallel u\parallel }_{{L}^{2}}\) produced by the POST_ERREUR operator.

4.4. notes#

The remarks are identical to those specified for modeling A.