v6.04.168 SSNV168 — Drained triaxial test with DRUCK_PRAGER softening behavior#
Summary:
This test case makes it possible to simulate a drained triaxial test on four different models during a non-linear calculation. This makes it possible to highlight the effect of the type of negative work hardening in the case of a AXIS or 3D model.
Modeling A:
« DRUCK_PRAGER » law of behavior with linear negative work hardening for a confinement of \(2\mathit{MPa}\).
QUAD4 mesh model AXISavec.
Modeling B:
« DRUCK_PRAGER » law of behavior with parabolic negative work hardening for a confinement of \(2\mathrm{MPa}\).
AXISavec modeling of QUAD4 meshes.
C modeling:
« DRUCK_PRAGER » law of behavior with linear negative work hardening for a confinement of \(2\mathrm{MPa}\).
3D modeling with HEXA20 meshes.
D modeling:
« DRUCK_PRAGER » law of behavior with parabolic negative work hardening for a confinement of \(2\mathrm{MPa}\).
3D modeling with HEXA20 meshes.
E modeling:
« DRUCK_PRAG_N_A » law of behavior with linear, parabolic and exponential hardening, for a confinement of \(2\mathrm{MPa}\)
QUAD4 mesh model AXISavec.
F modeling:
« DRUCK_PRAG_N_A » law of behavior with linear, parabolic and exponential hardening, for a confinement of \(2\mathrm{MPa}\)
3D model with HEXA20 meshes.