3. Modeling A#
3.1. Characteristics of modeling#
The modeling is 3D.
Contact method: contact formulation DISCRETE, active constraints algorithm, with REAC_GEOM =” CONTROLE “.
3.2. Characteristics of the mesh#
Number of knots: 8
Number of meshes and types: 2 HEXA8
3.3. Tested sizes and results#
Identification |
Reference type |
Reference value |
Tolerance |
DEPL, \(\mathit{DZ}\) at point \(\mathit{NH1}\) |
“ANALYTIQUE” |
-0.1 |
1.0E-6% |
DEPL, \(\mathit{DZ}\) at point \(\mathit{NH2}\) |
“ANALYTIQUE” |
-0.1 |
1.0E-6% |
DEPL, \(\mathit{DZ}\) at point \(\mathit{NH3}\) |
“ANALYTIQUE” |
-0.1 |
1.0E-6% |
DEPL, \(\mathit{DZ}\) at point \(\mathit{NH4}\) |
“ANALYTIQUE” |
-0.1 |
1.0E-6% |
DEPL, \(\mathit{DZ}\) at point \(\mathit{NB5}\) |
“ANALYTIQUE” |
-0.1 |
1.0E-6% |
DEPL, \(\mathit{DZ}\) at point \(\mathit{NB6}\) |
“ANALYTIQUE” |
-0.1 |
1.0E-6% |
DEPL, \(\mathit{DZ}\) at point \(\mathit{NB7}\) |
“ANALYTIQUE” |
-0.1 |
1.0E-6% |
DEPL, \(\mathit{DZ}\) at point \(\mathit{NB8}\) |
“ANALYTIQUE” |
-0.1 |
1.0E-6% |
REAC_NODA, \(\mathit{DZ}\) at point \(\mathit{NH1}\) |
“ANALYTIQUE” |
10000 |
1.0E-6% |
REAC_NODA, \(\mathit{DZ}\) at point \(\mathit{NH2}\) |
“ANALYTIQUE” |
10000 |
1.0E-6% |
REAC_NODA, \(\mathit{DZ}\) at point \(\mathit{NH3}\) |
“ANALYTIQUE” |
10000 |
1.0E-6% |
REAC_NODA, \(\mathit{DZ}\) at point \(\mathit{NH4}\) |
“ANALYTIQUE” |
10000 |
1.0E-6% |
REAC_NODA, \(\mathit{DZ}\) at point \(\mathit{NB5}\) |
“ANALYTIQUE” |
-10000 |
1.0E-6% |
REAC_NODA, \(\mathit{DZ}\) at point \(\mathit{NB6}\) |
“ANALYTIQUE” |
-10000 |
1.0E-6% |
REAC_NODA, \(\mathit{DZ}\) at point \(\mathit{NB7}\) |
“ANALYTIQUE” |
-10000 |
1.0E-6% |
REAC_NODA, \(\mathit{DZ}\) at point \(\mathit{NB8}\) |
“ANALYTIQUE” |
-10000 |
1.0E-6% |
3.4. notes#
The results obtained are perfect. The screening is going well.