5. Summary of results#
The test case allows a comparison of the results obtained from a thermal load and a field of initial constraints. It shows that the results are substantially equivalent.
More precisely in FEM (modeling A):
Conclusions on G:
Excellent independence of the results of CALC_G at the crowns (maximum difference between crowns less than 0.004%), in all cases,
Strictly identical results between an initial constraint field provided to CALC_Gde type ELGAet ELNO,
Results very similar to the reference, with the same crown (difference less than 0.01%). The closest results are obtained when the initial stress is given to the nodes at CALC_G,
Conclusions about K:
Same conclusions as on G, with double precision each time (maximum difference between crowns less than 0.002% and reference difference less than 0.005%)
It should be added that this same case gives the same results with the Abaqus software in its version 6.11 (method FEM, calculation of G only).