Summary of results ====================== The test case allows a comparison of the results obtained from a thermal load and a field of initial constraints. It shows that the results are substantially equivalent. More precisely in FEM (modeling A): * Conclusions on G: * Excellent independence of the results of CALC_G at the crowns (maximum difference between crowns less than 0.004%), in all cases, * Strictly identical results between an initial constraint field provided to CALC_Gde type ELGAet ELNO, * Results very similar to the reference, with the same crown (difference less than 0.01%). The closest results are obtained when the initial stress is given to the nodes at CALC_G, * Conclusions about K: * Same conclusions as on G, with double precision each time (maximum difference between crowns less than 0.002% and reference difference less than 0.005%) It should be added that this same case gives the same results with the Abaqus software in its version 6.11 (method FEM, calculation of G only).