4. B modeling#
4.1. Characteristics of modeling#
4.2. Characteristics of the mesh#
Number of knots: 2106
Number of meshes and types: 480 QUAD9
4.3. Tested sizes and results#
Identification |
Instants |
Reference |
% difference |
Critical load (mode 1) |
—104 797.82 N |
—6.834 |
|
Critical load (mode 2) |
104 797.82 N |
—6.834 |
4.4. notes#
The two critical loads obtained are similar in amplitude, but of opposite sign. The associated discharge methods are identical. In this test case, the critical load associated with the load applied corresponds to the first critical load found (Mode 1).