3. Modeling A#
3.1. Characteristics of modeling#
3.2. Characteristics of the mesh#
Number of knots: 3022
Number of meshes and types: 960 TRIA7
3.3. Tested sizes and results#
Identification |
Instants |
Reference |
% difference |
Critical load (mode 1) |
-104 797.82 N |
2.820 |
|
Critical load (mode 2) |
104 797.82 N |
2.940 |
3.4. notes#