20. R modeling#
20.1. Characteristics of modeling#
This modeling is used to verify the reconstruction of a field of type SIEF_ELGA in REST_REDUIT_COMPLET.
The primal basis on the movements DEPL is taken from the F modeling and the dual base on the field SIEF_ELGA was produced by Q modeling.
In addition, a partial base is also built on by selecting only the component SIXX.
20.2. Characteristics of the mesh#
The mesh contains 27 elements of type HEXA8.
20.3. Tested sizes and results#
The reference values are taken from the full calculation used to build the base SIEF_ELGA in Q modeling:
For the complete database (with all components):
Identification |
Reference type (Q modeling) |
Tolerance |
Mesh \({CellInRID}\) - SIEF_ELGA/SIXX —Point 1 |
|
|
Mesh \({CellInRID}\) - SIEF_ELGA/SIYY —Point 1 |
|
|
Mesh \({CellInRID}\) - SIEF_ELGA/SIZZ —Point 1 |
|
|
Mesh \({CellOutRID}\) - SIEF_ELGA/SIXX —Point 1 |
|
|
Mesh \({CellOutRID}\) - SIEF_ELGA/SIYY —Point 1 |
|
|
Mesh \({CellOutRID}\) - SIEF_ELGA/SIZZ —Point 1 |
|
|
For the partial base (with NOM_CMP =” SIXX “):
Identification |
Reference type (Q modeling) |
Tolerance |
Mesh \({CellInRID}\) - SIEF_ELGA/SIXX —Point 1 |
|
|
Mesh \({CellInRID}\) - SIEF_ELGA/SIYY —Point 1 |
|
|
Mesh \({CellInRID}\) - SIEF_ELGA/SIZZ —Point 1 |
|
|
Mesh \({CellOutRID}\) - SIEF_ELGA/SIXX —Point 1 |
|
|
Mesh \({CellOutRID}\) - SIEF_ELGA/SIYY —Point 1 |
|
|
Mesh \({CellOutRID}\) - SIEF_ELGA/SIZZ —Point 1 |
|
|
Apart from RID, SIYY = SIZZ =0 must be because the base is zero on these components.