11. Modeling I#

11.1. Characteristics of modeling#

A non-linear 3D thermal modeling is used.

This modeling tests the creation of empirical line modes in thermics. We take 3 modes maximum for the primal base and TOLE_SVD = 1.E-3 for the dual base.

11.2. Characteristics of the mesh#

The mesh contains 27 elements of type HEXA8.

11.3. Tested sizes and results#

We test some values of the primal base (as they are empirical modes, the tests are done to the nearest sign):

Identification

Reference type

Point \(({0,0,3})\) - TEMP -Mode 1

NON_REGRESSION

Point \(({0,0,3})\) - TEMP -Mode 2

NON_REGRESSION

Point \(({0,0,3})\) - TEMP -Mode 3

NON_REGRESSION

We test some values of the dual base (as they are empirical modes, the tests are done to the nearest sign):

Identification

Reference type

Point \(({0,0,3})\) - FLUX_NOEU/FLUY -Mode 1

NON_REGRESSION

Point \(({0,0,3})\) - FLUX_NOEU/FLUY -Mode 2

NON_REGRESSION

Point \(({0,0,3})\) - FLUX_NOEU/FLUX -Mode 3

NON_REGRESSION

11.4. notes#

We cannot say anything in absolute terms about the precision of these values because we are testing values of non-regression.