4. Summary of results#

This test case allows you to validate:

  • the MODI_MAILLAGE command associated with the SYMETRIE keyword,

  • the PROJ_CHAMP command associated with the DISTANCE_MAX keyword.

Validation is carried out over the entire temperature field and not only on a few points.

When the 2 commands are associated, it must be taken into account that the fields supported by nodes that belong to the symmetry plane can be counted twice.

When combining fields using the command CREA_CHAMP/OPERATION =” ASSE “, the structure of the first CHAM_NO is used as the reference structure. If the structure is incomplete, it is therefore necessary to create a reference CHAM_NO.