7. Model Ione#

7.1. Characteristics of modeling#

Same case as the previous modeling but in D_ PLAN_HS (really saturated modeling, gas flows no longer exist). The mesh consists of triangles.

Moreover, instead of applying a pressure gradient, the expected flow is applied directly at the outlet (the aim is to test the water flow limit condition for modeling D_ PLAN_HS.).

The expected results are the same.

7.2. Characteristics of the mesh#

Number of knots: 625

Number of meshes and types: 344 meshes, 60 SEG3et 284 TRIA6

7.3. Tested sizes and results#

Identification

Reference Type

Value

Tolerance ( \(\text{\%}\) )

Component \(\mathrm{INTE}\text{\_}\mathrm{FH11}\), location \(\mathrm{MDROITE}\)

“AUTRE_ASTER”

-2.0E-10

0.1%

Component \(\mathrm{INTE}\text{\_}\mathrm{FH11}\), location \(\mathrm{MMIL}\)

“AUTRE_ASTER”

2.0E-10

0.1%

Component \(\mathrm{INTE}\text{\_}\mathrm{FH11}\), location \(\mathrm{MGAUCHE}\)

“AUTRE_ASTER”

2.0E-10

0.1%