Model Ione ============= Characteristics of modeling ----------------------------------- Same case as the previous modeling but in D_ PLAN_HS (really saturated modeling, gas flows no longer exist). The mesh consists of triangles. Moreover, instead of applying a pressure gradient, the expected flow is applied directly at the outlet (the aim is to test the water flow limit condition for modeling D_ PLAN_HS.). The expected results are the same. Characteristics of the mesh ---------------------------- Number of knots: 625 Number of meshes and types: 344 meshes, 60 SEG3et 284 TRIA6 Tested sizes and results ------------------------------ .. csv-table:: "**Identification**", "**Reference Type**", "**Value**", "**Tolerance (** :math:`\text{\%}` **)**" "Component :math:`\mathrm{INTE}\text{\_}\mathrm{FH11}`, location :math:`\mathrm{MDROITE}` ", "'AUTRE_ASTER'", "-2.0E-10"," 0.1%" "Component :math:`\mathrm{INTE}\text{\_}\mathrm{FH11}`, location :math:`\mathrm{MMIL}` ", "'AUTRE_ASTER'", "2.0E-10"," 0.1%" "Component :math:`\mathrm{INTE}\text{\_}\mathrm{FH11}`, location :math:`\mathrm{MGAUCHE}` ", "'AUTRE_ASTER'", "2.0E-10"," 0.1%"