4. C modeling#
4.1. Characteristics of C modeling#
D_ PLAN_HH2SUDA modeling. This modeling corresponds to the modeling Finite Volumes decentralized on the edges for mobilities (Fickian terms are centered). The law of hydraulic coupling is LIQU_AD_GAZ_VAPE. The mesh consists of 200 TRIA7 elements.
4.2. Results#
The results are identical to those obtained with modeling finite volumes decentralized on the edge (modeling A).
4.3. Tested values#
We are doing tests on 3 nodes at \(t\mathrm{=}100s\).
On two nodes we compared the results to the analytical solution and on the third node we performed a non-regression test.
Points \((x,y)\) |
Time \((s)\) |
PRE1 Aster |
Relative error allowed ( \(\text{\%}\) ) |
\((\mathrm{0,075};0)\) \(\mathit{N360}\) |
100 s |
-1,33E+003 |
|
\((\mathrm{0,075};\mathrm{0,025})\) \(\mathit{N505}\) |
100 s |
-1,33E+003 |
|
\((1675;\mathrm{0,0158})\) \(\mathit{NT70}\) |
100 s |
-3,13E+002 |
|
Table 4.3-1: Tested values