5. C modeling#

5.1. Characteristics of C modeling#

Same as modeling A but in selective modeling: 3D_ HH2M_SI.

5.2. Tested sizes and results#

We recall that the temperature from the thermal calculation corresponds to the dry air pressure from our thermo-hydro-mechanical calculation. Since the vapour pressure is constant, we have:

_images/Object_87.svg

\(X(m)\)

Time \((s)\)

\(\mathit{PRE2}\)

Tolerance ( \(\text{\%}\) )

0.2

3E9

1.120E4

1%

0.2

5E9

1.223E3

1%

0.5

3E9

6570

1%

0.5

5E9

8685

1%

In addition, two non-regression tests are carried out on the Von Mises constraint (VMIS) and Tresca constraint (TRESCA).