4. B modeling#
4.1. Characteristics of B modeling#
Same as modeling A but in selective modeling: 3D_ HH2MS.
4.2. Tested sizes and results#
We recall that the temperature from the thermal calculation corresponds to the dry air pressure from our thermo-hydro-mechanical calculation. Since the vapour pressure is constant, we have:
\(X(m)\) |
Time \((s)\) |
|
Tolerance ( \(\text{\%}\) ) |
0.2 |
3E9 |
1.120E4 |
|
0.2 |
5E9 |
1.223E3 |
|
0.5 |
3E9 |
6570 |
|
0.5 |
5E9 |
8685 |
|
In addition, two non-regression tests are carried out on the Von Mises constraint (VMIS) and Tresca constraint (TRESCA).