5. Summary of results#
A relatively good agreement is obtained between the solution calculated with Code_Aster and the solution calculated by HERCULE:
Frequencies: the differences observed for the first 18 frequencies are small, less than \(\text{0.2\%}\).
Displacements: the observed differences are less than \(\text{1\%}\) if we use a quadratic combination of the directions of the excitations, and less than \(\text{2 \%}\) if we use a Newmark combination of the directions of the excitations.
Efforts: the differences observed are less than \(\text{2\%}\).