11. Summary of results#

The results obtained with the models TUYAU (SEG3 and SEG4) and TUYAU_6M (SEG4) are satisfactory. The maximum difference observed is less than \(\text{2.1\%}\).

The greatest natural frequency calculated is the same if we use the ergonomic way or if we exchange the roles of the matrices manually.