4. Summary of results#

The values of the natural frequencies and the eigenvectors are obtained with \(\text{< 0.3\%}\) precision.

The difference of \(\text{2.5\%}\) on the maximum arrows at points \(B\) and \(E\) would be worth verifying the reference solution, to complete the validation of the harmonic response.