Summary of results ====================== The values of the natural frequencies and the eigenvectors are obtained with :math:`\text{< 0.3\%}` precision. The difference of :math:`\text{2.5\%}` on the maximum arrows at points :math:`B` and :math:`E` would be worth verifying the reference solution, to complete the validation of the harmonic response.