**radial displacement (mm*)
**internal pressure (MPa*)
u2.05.04 User manual for limit load calculation#
Summary
The objective of this note is to provide the information necessary for a user to perform limit load calculations with*Code_Aster*.
The first part describes the main features of the method and its properties.
The second part shows the various steps required to implement in*Code_Aster*.
Finally, the third part presents some implementation remarks based on the Aster test case [V6.04.124] and on the industrial case aimed at determining the pressure limit for a Canopy tank joint.
- 1. Introduction
- 2. The main lines of the method
- 3. The implementation of boundary analysis
- 4. A few implementation notes
- 4.1. Representative test case: ssnv146a
- 4.2. More advanced calculation
- 4.3. Influence of the fineness of the meshes
- 4.4. Evolution of the estimate with the list of moments
- 4.5. Problems with symmetries
- 4.6. Comparison of limit analysis and incremental elastoplastic calculation up to ruin on an example
- 5. Bibliography