5. C modeling#
5.1. Characteristics of C modeling#
It is the same calculation as before but with axisymmetric modeling.
5.2. Tested values and results#
Capillary pressure and temperature profiles are presented for 3 moments and it is verified that the results are identical.

Figure 3.2.a: Comparison THM /thermal in axis-symmetry with an exchange term hydric
The results in HH2 refer to the results of the thermal calculation. The values of the right edge of the bar on which the exchange condition is applied are checked.
Tests are carried out on three values:
Points \((x,y)\) |
Time (\(s\)) |
PRE1 |
\((\mathrm{0,2};0)\) |
60 sec |
13888 |
1800 s |
32831 |
|
3600 s |
42829 |
To save time, models other than AXIS_THH2MS will only be tested for \(60s\).