5. C modeling#

5.1. Characteristics of C modeling#

It is the same calculation as before but with axisymmetric modeling.

5.2. Tested values and results#

Capillary pressure and temperature profiles are presented for 3 moments and it is verified that the results are identical.

_images/100000000000034A000002538823F805066C2234.png

Figure 3.2.a: Comparison THM /thermal in axis-symmetry with an exchange term hydric

The results in HH2 refer to the results of the thermal calculation. The values of the right edge of the bar on which the exchange condition is applied are checked.

Tests are carried out on three values:

Points \((x,y)\)

Time (\(s\))

PRE1

\((\mathrm{0,2};0)\)

60 sec

13888

1800 s

32831

3600 s

42829