10. Modeling E#

10.1. Characteristics of modeling#

Simulation at the hardware point.

10.2. Tested sizes and results#

The solutions are post-treated at the single point of the model and compared to non-regression values in terms of the number of liquefaction cycles \(\mathit{NCYCL}\) for:

Criterion number 1: \(\text{RU\_MAX}=0.705\)

Identification

Reference type

Reference value

Tolerance

\(\text{PRES\_CONF}=50\mathit{kPa}\)

“NON_REGRESSION”

0

0.0001%

\(\text{PRES\_CONF}=100\mathit{kPa}\)

“NON_REGRESSION”

1

0.0001%

\(\text{PRES\_CONF}=150\mathit{kPa}\)

“NON_REGRESSION”

1

0.0001%

Criterion number 2: \(\text{RU\_MAX}=0.705\phantom{\rule{2em}{0ex}}+\phantom{\rule{2em}{0ex}}\text{EPSI\_ABSO\_MAX}=5\text{\%}\)

Identification

Reference type

Reference value

Tolerance

\(\text{PRES\_CONF}=50\mathit{kPa}\)

“NON_REGRESSION”

0

0.0001%

\(\text{PRES\_CONF}=100\mathit{kPa}\)

“NON_REGRESSION”

3

0.0001%

\(\text{PRES\_CONF}=150\mathit{kPa}\)

“NON_REGRESSION”

1

0.0001%