4. B modeling#

4.1. Characteristics of modeling#

Modeling POU_D_T_GD

_images/100002010000021B0000019754AC1389B456A00C.png

Cutting: 8 elements in the length of the arc

4.2. Characteristics of the mesh#

Number of knots: 9

Number of meshes and types: 8 SEG2

4.3. Tested sizes and results#

Charging is applied in 60 load steps.

Load

Coordinates

Reference

Reference Type

Tolerance

\(F\mathrm{=}300N\)

\(X\)

22.28

“SOURCE_EXTERNE”

2%

\(Y\)

58.74

“SOURCE_EXTERNE”

2%

\(Z\)

40.12

“SOURCE_EXTERNE”

3%

\(F\mathrm{=}\mathrm{600N}\)

\(X\)

15.67

“SOURCE_EXTERNE”

3%

\(Y\)

46.99

“SOURCE_EXTERNE”

3%

\(Z\)

53.52

“SOURCE_EXTERNE”

1%

4.4. Graphical results of B modeling#

_images/100000000000034900000251D562CC8DC3D41FE4.png