4. Summary of results#
The figure below shows the distribution of the dissipation indicator in the joint.
It should be noted that in terms of robustness, a certain number of numerical parameters have not been tested, in particular the influence of:
time patterns for irregular dynamics,
penalty parameters for joints,
influence of the mesh.
The test verifies the correct functioning in dynamics of the cohesive zone elements (CZM_EXP_REG).