2. Benchmark solution#
2.1. Calculation method#
The test case is non-regression. It is used to perform dynamic CZM_EXP_REGen functionality checks.
2.2. Reference quantities and results#
We test the internal variables VARI_NOEU:
V2: Dissipation indicator (0=discharge,1=dissipation)
V4: damage indicator or percentage of surface energy dissipated (0 healthy joint, 1 broken joint, 0<V4<1 damaged joint)
Knots tested on the joint opening line at instant \(\mathrm{0,00825}s\):
N6 (10, -0.1)
N116 (20.2847, -0.1)
N110 (29.891, -0.1)
N106 (40.7025, -0.1)
N101 (62.6306, -0.1)
2.3. Uncertainties about the solution#
Non-regression tests.