2. Benchmark solution#

2.1. Calculation method#

The test case is non-regression. It is used to perform dynamic CZM_EXP_REGen functionality checks.

2.2. Reference quantities and results#

We test the internal variables VARI_NOEU:

  • V2: Dissipation indicator (0=discharge,1=dissipation)

  • V4: damage indicator or percentage of surface energy dissipated (0 healthy joint, 1 broken joint, 0<V4<1 damaged joint)

Knots tested on the joint opening line at instant \(\mathrm{0,00825}s\):

  • N6 (10, -0.1)

  • N116 (20.2847, -0.1)

  • N110 (29.891, -0.1)

  • N106 (40.7025, -0.1)

  • N101 (62.6306, -0.1)

2.3. Uncertainties about the solution#

Non-regression tests.