Summary of results ====================== The figure below shows the distribution of the dissipation indicator in the joint. It should be noted that in terms of robustness, a certain number of numerical parameters have not been tested, in particular the influence of: * time patterns for irregular dynamics, * penalty parameters for joints, * influence of the mesh. The test verifies the correct functioning in dynamics of the cohesive zone elements (CZM_EXP_REG). .. image:: images/100000000000047E0000027B2DAAD793E5C44160.png :width: 6.1417in :height: 3.2244in .. _RefImage_100000000000047E0000027B2DAAD793E5C44160.png: Distribution of the dissipation indicator in the joint --------------------------------------------------------