5. C modeling#

5.1. Characteristics of modeling#

Modeling identical to modeling A except for the use of 3D modeling_ DIAG instead of 3D. It makes it possible to validate the use of an anisotropic coordinate system with massive 3D_ DIAG thermal elements.

5.2. Characteristics of the mesh#

Set to 250 HEXA8 (5 elements on edges \(\mathrm{HD}\) and \(\mathrm{DM}\), 10 elements on \(\mathrm{DF}\) by IDEAS.

5.3. Tested values#

Identification

Reference

T (A) * N1

100

T (B) N133

50

\(\phi (A)\mathrm{.}Y\)

15.9155

*: imposed temperature

5.4. notes#

The symmetry of the mesh means that solution \(T\) at the nodes of the mesh is accurate, but in the elements, the extrapolated solution is not exact.