C modeling ============== Characteristics of modeling ----------------------------------- Modeling identical to modeling A except for the use of 3D modeling_ DIAG instead of 3D. It makes it possible to validate the use of an anisotropic coordinate system with massive 3D_ DIAG thermal elements. Characteristics of the mesh ---------------------------- Set to 250 HEXA8 (5 elements on edges :math:`\mathrm{HD}` and :math:`\mathrm{DM}`, 10 elements on :math:`\mathrm{DF}` by IDEAS. Tested values --------------- .. csv-table:: "**Identification**", "**Reference**" "T (A) * N1", "100" "T (B) N133", "50" ":math:`\phi (A)\mathrm{.}Y` ", "15.9155" *: imposed temperature notes --------- The symmetry of the mesh means that solution :math:`T` at the nodes of the mesh is accurate, but in the elements, the extrapolated solution is not exact. The flow is calculated by*Aster* at the points where the elements are integrated and then transferred to the nodes by extrapolation. As the flow is not uniform, this extrapolation leads to a difference between calculation and reference.