5. C modeling#

5.1. Characteristics of modeling#

All the piping is modelled in TUYAU_6M (6 Fourier modes).

5.2. Characteristics of the mesh#

86 stitches SEG3

5.3. Tested values#

Load case

Point movement \(D\)

Reference

Aster

% diff

\(\mathrm{Mz}=17000\mathrm{Nm}\)

\(\mathrm{DY}(\mathrm{mm})\)

0.02

0.0199

0.01

\(\mathrm{My}=17000\mathrm{Nm}\)

\(\mathrm{DZ}(\mathrm{mm})\)

—0.015657

—0.01598

2