2. Benchmark solution#
2.1. Calculation method used for the reference solution#
The reference solution comes from a first calculation with ASTER with the quadricayer described in the reference problem.
2.2. Benchmark results#
They consist of the values of the displacement field \(\mathrm{DX},\mathrm{DY},\mathrm{DZ},\mathrm{DRX},\mathrm{DRY}\) at point \(\mathrm{A3}\) (node \(\mathrm{N1}\) for ASTER) and at node \(\mathrm{N10}\) with coordinates \((\mathrm{9,2}\mathrm{,0})\).
2.3. Uncertainty about the solution#
Null, since it is the same calculation carried out by two different ways.