3. Modeling A#

3.1. Characteristics of modeling#

This modeling is based on linear meshing. The 9 surface meshes (QUAD4) of each plate are affected by the DKT model.

3.2. Calculations and loads#

Two calculations are carried out on each plate of the mesh. Calculation loads are detailed on group COQ_X. Then simply replace \(X\) by \(Y\) and then \(Z\) to get the loads of the other calculations.

3.2.1. Reference calculation, pre-deformation defined by value#

In the reference calculation, the following pre-deformation values are assigned:

G1X

G2X

G3X

EPXX

1E-3

2E-3

3E-3

3E-3

EPYY

2E-3

4E-3

6E-3

EPXY

3E-3

6E-3

9E-3

9E-3

KXX

4E-3

8E-3

12E-3

KYY

5E-3

10E-3

15E-3

15E-3

KXY

6E-3

12E-3

18E-3

18E-3

The dependence on time is taken into account by adding an « identity » multiplier function to the load.

3.2.2. Second calculation, pre-deformation defined by function#

The following pre-deformation load is affected on all the cells of plate COQ_X:

EPXX

\(\mathrm{1E-3.}\mathit{escalier}(X)\mathrm{.}\mathit{INST}\)

EPYY

\(\mathrm{2E-3.}\mathit{escalier}(X)\mathrm{.}\mathit{INST}\)

EPXY

\(\mathrm{3E-3.}\mathit{escalier}(X)\mathrm{.}\mathit{INST}\)

KXX

\(\mathrm{4E-3.}\mathit{escalier}(X)\mathrm{.}\mathit{INST}\)

KYY

\(\mathrm{5E-3.}\mathit{escalier}(X)\mathrm{.}\mathit{INST}\)

KXY

\(\mathrm{6E-3.}\mathit{escalier}(X)\mathrm{.}\mathit{INST}\)

3.3. Tested sizes and results#

Calculation on COQ_X :

Baseline calculation:

Identification

T reference type

Reference values

Tolerance

Instant 1, FLX, DX

“NON_REGRESSION”

Instant 1, FLX, DY

“NON_REGRESSION”

Instant 1, FLX, DZ

“NON_REGRESSION”

Instant 2, FLX, DX

“NON_REGRESSION”

Instant 2, FLX, DY

“NON_REGRESSION”

Instant 2, FLX, DZ

“NON_REGRESSION”

Second calculation:

Identification

T reference type

Reference values

Tolerance

Instant 1, FLX, DX

“AUTRE_ASTER”

0.00631037083998

1E-6

Instant 1, FLX, DY

“AUTRE_ASTER”

0.0327934215069

1E-6

Instant 1, FLX, DZ

“AUTRE_ASTER”

-0.011685267293

1E-6

Instant 2, FLX, DX

“AUTRE_ASTER”

0.01262074168

1E-6

Instant 2, FLX, DY

“AUTRE_ASTER”

0.0655868430138

1E-6

Instant 2, FLX, DZ

“AUTRE_ASTER”

-0.023370534587

1E-6

Calculation on COQ_Y :

Baseline calculation:

Identification

T reference type

Reference values

Tolerance

Instant 1, FLY, DX

“NON_REGRESSION”

Instant 1, FLY, DY

“NON_REGRESSION”

Instant 1, FLY, DZ

“NON_REGRESSION”

Second calculation:

Identification

T reference type

Reference values

Tolerance

Instant 1, FLY, DX

“AUTRE_ASTER”

-0.0392065784931

1E-6

Instant 1, FLY, DY

“AUTRE_ASTER”

0.00631037083998

1E-6

Instant 1, FLY, DZ

“AUTRE_ASTER”

-0.0468734663462

1E-6

Calculation on COQ_Z :

Baseline calculation:

Identification

T reference type

Reference values

Tolerance

Instant 1, FLZ, DX

“NON_REGRESSION”

Instant 1, FLZ, DY

“NON_REGRESSION”

Instant 1, FLZ, DZ

“NON_REGRESSION”

Second calculation:

Identification

T reference type

Reference values

Tolerance

Instant 1, FLZ, DX

“AUTRE_ASTER”

0.0116852672935

1E-6

Instant 1, FLZ, DY

“AUTRE_ASTER”

0.0327934215069

1E-6

Instant 1, FLZ, DZ

“AUTRE_ASTER”

0.00631037083998

1E-6