10. H modeling#

10.1. Characteristics of H modeling#

Axisymmetric modeling THH2S with locked temperatures. 20 elements QUAD8.

Discretization in time: 100 \(5E7s\) time steps each.

10.2. Tested sizes and results#

\(X\) ( \(m\) )

Time ( \(s\) )

\(\mathit{PRE2}\) Aster

\(\mathit{PRE2}\) thermal calculation

Tolerance

\(0.2\)

\(3{10}^{9}\)

\(7944\)

\(7900\)

\(10\text{\%}\)

\(0.2\)

\(5{10}^{9}\)

\(9560\)

\(9500\)

\(10\text{\%}\)

The values obtained by Code_Aster are tested in non-regression to a tolerance of \(0.01\text{\%}\) .H modeling