5. B modeling#

5.1. Characteristics of modeling#

The cell is homogenized in PLAQUE in order to obtain the parameters for a plate model.

Homogenized coefficients

[]

Calculation ASTER

Relative error (%) :math: frac {left|text {approximate value} -text {theoretical value}right|} {left|text {theoretical value}right|}ast 100

\({C}_{\text{1111}}\) (MEMB_L)

0.43865

0.43883444

0.042%

\({C}_{\text{2222}}\) (MEMB_T)

\({C}_{\text{1212}}\) (MEMB_G_LT)

0.15493

0.15499162

0.04%

\({C}_{\text{1122}}\) (MEMB_LT)

0.07747

0.07726186

0.269%

\({D}_{\text{1111}}\) (FLEX_L)

0.43789

0.43849126

0.137%

\({D}_{\text{2222}}\) (FLEX_T)

\({D}_{\text{1212}}\) (FLEX_G_LT)

0.15477

0.15500363

0.151%

\({D}_{\text{1122}}\) (FLEX_LT)

0.07824

0.07759885

0.819%