5. B modeling#
5.1. Characteristics of modeling#
The cell is homogenized in PLAQUE in order to obtain the parameters for a plate model.
Homogenized coefficients |
[] |
Calculation ASTER |
Relative error (%) :math: frac {left|text {approximate value} -text {theoretical value}right|} {left|text {theoretical value}right|}ast 100 |
\({C}_{\text{1111}}\) (MEMB_L) |
0.43865 |
0.43883444 |
0.042% |
\({C}_{\text{2222}}\) (MEMB_T) |
– |
– |
– |
\({C}_{\text{1212}}\) (MEMB_G_LT) |
0.15493 |
0.15499162 |
0.04% |
\({C}_{\text{1122}}\) (MEMB_LT) |
0.07747 |
0.07726186 |
0.269% |
\({D}_{\text{1111}}\) (FLEX_L) |
0.43789 |
0.43849126 |
0.137% |
\({D}_{\text{2222}}\) (FLEX_T) |
– |
– |
– |
\({D}_{\text{1212}}\) (FLEX_G_LT) |
0.15477 |
0.15500363 |
0.151% |
\({D}_{\text{1122}}\) (FLEX_LT) |
0.07824 |
0.07759885 |