v6.01.114 SSNA114 - Drained triaxial test with model VISC_MAXWELL#

Summary

This test validates model VISC_MAXWELL. It is a triaxial test in pure mechanics (in drained condition). The calculations are applied only to the solid part and the hydraulic coupling is not taken into account. For reasons of symmetry, only one eighth of a sample subjected to a triaxial test is interested in.

The lockdown level is 5 bars.