4. Summary of results#
The results obtained are excellent. The values calculated by*Aster* are the same as the reference values. This is a « normally expected » result since the solution field, which is linear, belongs to the interpolation space of the element under test.
This test allowed the following commands to be tested:
DEFI_NAPPE allowing you to define a variation in the outside temperature as a function of the abscissa \(x\) and the ordinate \(y\),
DEFI_MATERIAU associated with the keyword THER_ORTH, making it possible to define the characteristics of an orthotropic material,
AFFE_CARA_ELEM associated with the MASSIF keyword, allowing to define orthotropy axes.