2. Benchmark solution#

2.1. Calculation method used for the reference solution#

The reference solution is the one given in sheet TPLA06 /89 of the guide VPCS

_images/100000000000015A0000008111AA19A0D1229856.png
  • Temperature according to \(z\): \(T(z)={T}_{1}\frac{\mathrm{sinh}(\mathrm{az})}{\mathrm{sinh}(\mathrm{aL})}\) or \(a=\sqrt{(\frac{\mathrm{2h}}{\lambda r})}\)

  • \(T(z=0)=0\) \(T(z=L)={T}_{1}\).

2.2. Benchmark results#

Temperature in \(z=0.,0.1,0.2,\mathrm{...},0.8,0.9,1.0\)

2.3. Uncertainty about the solution#

\(<1\text{\%}\)

Approximate analytical solution (approximation: \(T=\mathrm{cte}\), for all \(r\))

2.4. Bibliographical references#

  1. Guide to the validation of structural calculation software packages. French Society of Mechanics, AFNOR 1990 ISBN 2-12-486611-7