v3.04.159 SSLV159 - Cantilever girder subject to static boom loading#

Summary:

This test makes it possible to validate the connection between 1D and 3D models, in the Arlequin framework (3D_ POU_ARLEQUIN) [1].

It is a cantilever beam model, embedded at one end and subject to static boom loading at the other end.

The results of the calculations are compared with those obtained by CODE_aster with a 1D reference model and a 1D-3D mixed model connected with the 3D_ POU option. The results coincide perfectly with the reference solutions.