v3.01.005 SSLL05 — bimetal: embedded beams connected by a dimensionally stable element#
Summary:
The static linear elasticity test is used to validate straight beam elements POU_D_T.
This test case concerns embedded beams connected by a non-deformable element.
The support reactions and bending moments as well as the deflection are tested by comparing simulation results with the reference solution AFNOR (ref. [1]) as well as those obtained with the Pipestress software.