2. Reference solution — Modeling A#

The reference is obtained by a Code_Aster calculation with classical Euler beam elements (POU_D_E). The characteristics for this reference calculation are obtained by homogenizing the steel-concrete section:

Section:

_images/Object_1.svg

Quadratic moment:

_images/Object_2.svg

The density selected is that of concrete (the weight of steel is neglected).