5. C modeling#

5.1. Characteristics of modeling#

We use a POU_D_TGM model.

5.2. Characteristics of the mesh#

The mesh contains 2 elements of type SEG2.

5.3. Tested sizes and results#

Static calculation:

The value of the DZ component on the node N3 is tested in non-regression.

Field

Component

Reference Value

Tolerance

EPOT_ELEM

TOTALE

\(230.67091447835\)

\(1.E-6\)

Modal calculation:

The value of frequency 7 is tested in non-regression.

Field

Component

Reference Value

Tolerance

EPOT_ELEM

TOTALE

\(94759.34489198\)

\(1.E-6\)